[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: 240 volts on tangaras and the 4d set
Scott Beecham wrote:
> Yup It is exactly the same on at least one of the tangaras up here, I only
> noticed it the other day. I was actually going to ask somebody if it is
> always always powered up and what it would be used for(I'm guessing cleaning
> purposes).
It was installed to run vacuum cleaners, etc. It is powered by the 1500V
inverter which outputs three phase 415V power to run all auxiliaries n the train
(like A/C, headlights, etc). The supply is fairly clean and constant, except
when the Static Inverter drops out under heavy braking. I have done a lot of
work on tangaras with expensive computer equipment plugged in, but we used a UPS
for when the SIV shut down.
--
David Johnson
trainman@ozemail.com.au
http://www.ozemail.com.au/~trainman/