[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Brief Signalling failure at Camberwell




"Sam Eades" <seades@bigpond.net.au> wrote in message
11cA6.529$wP3.3566@news-server.bigpond.net.au">news:11cA6.529$wP3.3566@news-server.bigpond.net.au...
>
> "Paul Hambleton" <phambleton@labyrinth.net.au> wrote in message
> fnaA6.12$Z53.2560@vic.nntp.telstra.net">news:fnaA6.12$Z53.2560@vic.nntp.telstra.net...
> > A bit of excitement this morning at Camberwell.
> > As the 1023 UP from Alamein approached platform 2, all the signals went
> out.
> > No lights whatsoever. The driver dutifully stopped at the automatic signal
> > guarding entry into platform 2 before proceeding into the platform. All
> the
> > signals then came back on displaying red before normal operations resumed.
> > Anyone know what happened.
>
> Sounds like a power surge or a brief power failure. With a power surge, all
> of the circuit breakers have to reset, then all track circuits "drop"
> causing signals to go to normal (stop). The signaller then needs to run the
> time releases to put them back to proceed (usually 1 to 2 mins)
>
> Sam

Strangely enough, this happens on a very regular basis, at least once a week.